home hemodialysis, Buttonhole, uncture technique, patient trainingAbstract
Home hemodialysis requires total autonomy from the patient, who punctures himself.
To this end, the vascular approach must be of good quality and the puncture technic should be easy to handle.
A recognized approach is the "Buttonhole" technique. An easy technique, it encourages patients to continue their dialysis at home.
But the risk of arterio-venous fistula (AVF) infection related to the puncture of the "Buttonhole" is very high. However, this technique has many positive points for the AVF itself, for the patients and for the caring teams.
We looked for ways to improve this technique and eliminate as much as possible the risk of infection and to maintain the functionality of the fistula. We present our experience in this field.
References
Réforme des normes et du financement de la dialyse. Position du CA du GNFB. ». available at : https://organesdeconcertation.sante.belgique.be/sites/default/files/documents/nationale_raad_voor_ziekenhuisvoorzieningen-fr/cneh_d_437-1_-_annexe_2_-_normes_dialyse_ca_gnfb_df_2_3.pdf
Convention avec l’hôpital «NOM» relative au financement de la dialyse ». institut National d’Assurance Maladie-invalidité, Service des Soins de Santé, Avenue de Tervuren 211, 1150 Bruxelles. available at : https://www.inami.fgov.be
« Grandeur et Dangers des Cathéters Veineux Centraux. » Dr. M. François, CHRU, Hôpitaux DE Tours, SFAV, juin 2016. available at Disponible sur : www.sfav.org
« Quels sont les différents abords vasculaires d’hémodialyse ? » SCVE Societé de Chirurgie Vasculaire et Endovasculaire de Langue Française, 2019. available at : http://www.vasculair.com
« Piquage de la fistule arterio-veineuse : Avantages et Inconvénients de la méthode de la boutonnière » B. Gombert, 19/07/2014 . available at : https://nephrohug.wordpress.com
« Fistula First : Vascular Access Update, Continuing Education », « The Buttonhole Technique for Arteriovenous Fistula Cannulation » , Lynda K. Ball, Nephrology . Nursing Journal, May- Juine 2006, vol.33 No.3. available at : http://scholar.google.be
« Canulation in haemodialysis : rope-ladder or buttonhole technique ? » Annemarie M. Verhallen, Menno P. Kooistra, Brigit C. Van Jaarsveld, Nephrology Dialysis Transplantation, Volume22, Issu 9, Septembre 2007, pages 2601-2604, available at : https://doi.org/10.1093/ndt/gfm043
« The salvage of aneurysmal fistule utilizing a modified buttonhole cannulation technique and multiple cannulators » Rosa M. Marticorena, Joyce A. Hunter, et al. M. Bolocan Goldstein, 2006. available at : https://doi.org/10.1111/j.1542-4758.2006.00094.x
« Moderator’s View :Buttonhole canulation of arteriovenous fistulae : great caution is warranted » L. Labriola and M. Jadoul, Department of Nephrology, Clinique Universitaires Saint-Luc, Université catholique de Louvain, Brussels,Belgium, 2016. available at : https://www.ncbi.nlm.nih.gov
« Buttonhole, une technique de ponction en auto dialyse » K. Charytoniuk , DEH Erasme. available at : http://www.rdplf.org/biblio/category/30-fistule-et-catheter.html, (ask secretaire for login)
« Ponction en « Buttonhole » pratique en DEH à l’hôpital Erasme » K. Charytoniuk . 23éme Cours Congres de la Societé Française de l’AbordVasculaire. Available at : www.sfav.org
Downloads